2020-3-25 · BOILER INTERVIEW QUESTION amp; ANSWER Today we discussed about some multiple choice questions and answer related to power plant these questions are very helpful for which do preparation for B.O.E ( BOILER OPERATION ENGINEER ) EXAM. and also for ENERGY MANGER EXAM, and also for those people which prepared
GET A QUOTE2018-1-19 · The high pressure feed water is supplied to the boiler through this valve. This valve opens towards the boiler only and feeds the water to the boiler. If the feed water pressure is less than the boiler steam pressure then this valve remains closed and prevents the back flow of steam through the valve.
GET A QUOTE2020-4-11 · Boiler or more specifically steam boiler is an essential part of thermal power plant.. Definition of Boiler. Steam boiler or simply a boiler is basically a closed vessel into which water is heated until the water is converted into steam at required pressure. This is most basic definition of boiler.. Working Principle of Boiler
GET A QUOTE2018-8-5 · Determining the proper boiler load is important because when a boiler is oversized for its load, it tends to fire in the lower range (below 50%) where excess air typically is the highest. High excess air causes a 1% loss in efficiency for every 2% increase over the optimal safe oxygen level, which normally occurs in the 80%-and-higher firing range.
GET A QUOTEThe National Board of Boiler and Pressure Vessel Inspectors was created in 1919 to promote greater safety to life and property through uniformity in the construction, installation, repair, maintenance, and inspection of pressure equipment.
GET A QUOTE2020-4-10 · The pressure-reducing valve may be obstructed or defective and no water may get through into the boiler. The pressure-reducing valve may have failed and the water pressure in the boiler system may be too high. There may be a problem with the valve or dirt may be obstructing the valve. It's also remotely possible the valve was installed backwards.
GET A QUOTE2011-3-28 · high, av). (c) Increasing the boiler pressure (Increases T high, av). Lowering the Condenser Pressure (Lowers T low, av) Steam exists as a saturated mixture in the condenser at the saturation temperature corresponding to the pressure inside the condenser. Therefore, lowering the operating pressure of the condenser automatically lower the
GET A QUOTE2012-6-28 · 6 Design of an industrial boiler 7 How an industrial boiler system works 8 The use It will be best to get out your note pad and write down what you read; after spending a short time learning it by heart, you will be able to show off your unexpected knowledge at the next family The boiler pressure vessel is a horizontal, cylindrical tube
GET A QUOTE2020-4-10 · sure boiler with a unit capacity of more than 1000 MW, the BFP is required to deliver a very high level of per-formance such as a flow rate of approximately 1700 t/h, a discharge pressure of approximately 30 MPa, and a shaft power of approximately 20000 kW. To achieve this high pressure, the BFP is required to achieve a
GET A QUOTEThese washers are for tubular sight-glasses on steam boilers and other high pressure aggressive applications. Typically, rubber sight-glass washers last only a few months before cracking amp; leaking but these tough Teflon washers are made to withstand higher temperatures and
GET A QUOTE2020-4-3 · ASME - International Boiler and Pressure Vessel Code - The International Boiler and Pressure Vessel Code establishes rules of safety governing the design, fabrication, and inspection of boilers and pressure vessels, and nuclear power plant components during construction; Boiler Blowdown Rate - Calculating boiler blowdown rate
GET A QUOTEFor any one boiler, if the heat transfer rate (q_dot - body text.jpg) is increased, the maximum allowable boiler pressure is reduced. A compromise is reached with a furnace tube wall thickness of between 18 mm and 20 mm. This translates to a practical pressure limit for shell boilers of around 27 bar.
GET A QUOTE2020-4-11 · When there is a decrease in demand, the drum pressure increases and the firing rate changes, thus reducing the volume of the bubbles (i.e., bubbles get smaller). A sudden loss in load could result in high drum pressure causing shrinkage severe enough to trip the boiler on low level. A boiler trip at high firing rates creates a furnace implosion.
GET A QUOTEThe boiler pressure gauge read 12 psi. The boiler operating pressure control was set for 15 psi. Steam was spewing from the boiler feed vent like an old locomotive. I adjusted the operating pressure control to the normal steam pressure. Within a short time, the boiler operated the way it was supposed to and the building had heat.
GET A QUOTENOTE: The air pressure should not exceed 35 psi at high fire. Greater air pressure causes excessive wear of the air pump, increases lute oil usage, and can overload the motor, thus causing damage to the equipment. Abnormally high pressure indicated on the nozzle air pressure is an indication that the burner nozzle has become clogged.
GET A QUOTEshort note on boilers water tube Gas Fired Water Tube Hot Water Boiler - ston 2019-10-12 · The structure of SZS gas fired water tube hot water boiler is arranged as double drums and longitudinal type "D" shape, it's quickly assembled boiler with water tubes, has the characteristics sufficient output, high
GET A QUOTE2020-3-25 · BOILER INTERVIEW QUESTION amp; ANSWER Today we discussed about some multiple choice questions and answer related to power plant these questions are very helpful for which do preparation for B.O.E ( BOILER OPERATION ENGINEER ) EXAM. and also for ENERGY MANGER EXAM, and also for those people which prepared
GET A QUOTEBoiler Questions and Answers | Boiler Repair Help for Boiler Problems. Note: You do not need to have the boiler at Maximum Fire for and hour. You can take the reading over a few minutes and correct to one hour. These never hold up well on a high pressure boiler. They tend to
GET A QUOTEBoiler Questions and Answers | Boiler Repair Help for Boiler Problems. Note: You do not need to have the boiler at Maximum Fire for and hour. You can take the reading over a few minutes and correct to one hour. These never hold up well on a high pressure boiler. They tend to
GET A QUOTEWhy the High Pressure Boiler ? • Where 30 bar pressure amp; steam rate of 30 tones/hour is required the fire tube boilers are preferred due to lower cost. • In the power plant it is necessary to produce the steam at high pressure, high rate and high efficiency.
GET A QUOTE